The first operational experiences with exhaust air treatment plants according to the
30th Federal Immission Control Regulation (30th BImSchV) show that the required
exhaust air limit values can be met with sufficiently dimensioned individual components
(acid washer and RTO, if necessary biofilter for partial flows of low pollution).
With regard to the operational safety and to the availability of the plants closely related
to it, already in the first months of the "30th BImSchV age" in part considerable
problems with corrosion as well as blockages of the heat exchangers by silicon oxide
in the RTO were observed. A sufficient dimensioning of the exhaust air treatment
capacity as well as a redundant layout of the RTO gain considerable importance with
regard to the plant availability required by the 30th BImSchV. Apart from the described
technical optimization measures there are economic optimization Potentials.
These should be checked for the individual case when a long-term stable operation
of the exhaust air treatment plants is reached, and then realized optionally.
Copyright: | © HAWK Hochschule für angewandte Wissenschaft und Kunst - Fakultät Ressourcenmanagement | |
Quelle: | 67. Informationsgespräch (September 2006) | |
Seiten: | 0 | |
Preis inkl. MwSt.: | € 0,00 | |
Autor: | Prof. Dr. Rainer Wallmann Dipl.-Ing. Jürgen Hake Prof. Dr.-Ing. Klaus Fricke Dr.-Ing. Heike Santen Dipl.-Ing. Helge Dorstewitz | |
Artikel weiterleiten | Artikel kostenfrei anzeigen | Artikel kommentieren |
Weiterentwicklung der MBA mit vorgeschalteter Trockenvergärung der Feinfraktion
© Witzenhausen-Institut für Abfall, Umwelt und Energie GmbH (4/2023)
Die Integration einer neuen Vergärungsstufe in die bestehende biologische Trocknungsanlage (BA) am Standort Ennigerloh erfordert umfangreiche Voruntersuchungen zu Auslegungsmengen und Stoffkennwerten des Eintrags sowie zu den Auswirkungen auf Massen- und Energiebilanzen des Gesamtprozesses.
Anhand von verfahrens- und anlagenspezifischen Bilanzmodellen sowie Variantenvergleichen werden geeignete Auslegungs- und Verfahrensvarianten identifiziert und es wird eine belastbare Datengrundlage zur Auswahl von Vorzugsvarianten geschaffen.
Development of local municipal solid waste management in the Western Transdanubia region of Hungary
© Lehrstuhl für Abfallverwertungstechnik und Abfallwirtschaft der Montanuniversität Leoben (11/2020)
Hungarian municipal solid wastes (MSW) management has developed tremendously over the past 15 years. More than 3,000 landfills and dumps had been closed, just to mention one improvement. However, still, lots of work is necessary to accomplish the EU’s ambitious aim of decreasing landfilling and increasing recycling and composting.
Thermochemische Vorbehandlung – Erste Erkenntnisse am Fallbeispiel einer an Organik reichen Feinfraktion
© Lehrstuhl für Abfallverwertungstechnik und Abfallwirtschaft der Montanuniversität Leoben (11/2020)
Aufgrund des in Österreich geltenden Verbots der Deponierung von Abfällen mit einem Anteil an organischem Kohlenstoff im Feststoff von mehr als fünf Massenprozent (BMLFUW 2008) ist eine Behandlung dieser vor der Deponierung erforderlich. Die mechanisch-biologische sowie die thermische Behandlung stellen bewährte Verfahren dar. Im Burgenland wird, wie in zahlreichen anderen Regionen auch, der gemischte Siedlungsabfall in einer mechanisch-biologischen Abfallbehandlung aufbe-reitet. Das Ziel der MBA ist die Herstellung von Ersatzbrennstoffen zur thermischen Verwertung und stabilisierter Fraktionen zur Deponierung. Im vorliegenden Beitrag werden die ersten Ergebnisse der thermochemischen Vorbehandlung als Behandlungsalternative zur biologischen Stufe in einer MBA beschrieben.
Charakterisierung von belüftetem Deponiematerial betreffend Verwertbarkeit und Ablagerfähigkeit
© Lehrstuhl für Abfallverwertungstechnik und Abfallwirtschaft der Montanuniversität Leoben (11/2018)
Als ein Teil der Erfolgskontrolle nach dreijähriger Belüftung eines Deponieabschnitts der Kreismülldeponie Konstanz wurde eine umfangreiche Probenahme- und Analysenkampagne durchgeführt. Ziel war darzustellen, mit welchem Aufwand sich von dem behandelten Deponiegut Wertstoffe abtrennen lassen, in welchem Zustand sich diese befinden und ob der Sortierrest sich ohne weitere Vorbehandlung auf einer MBA-Deponie ablagern ließe.
Perspektiven der mechanischen, mechanisch-biologischen und der stoffstromspezifischen Abfallbehandlung
© Witzenhausen-Institut für Abfall, Umwelt und Energie GmbH (4/2018)
Die aktuellen Veränderungen der europäischen und nationalen Energie- und Umweltpolitik sowie der demografische Wandel werden sich langfristig direkt oder indirekt auf die Abfallströme, deren Zusammensetzungen, Mengen und Verwertungswege auswirken.